Aim: To provide the knowledge and design skills to develop a residential electrical wiring system as per regulation standards. Learning Outcome: Selection and Design of cable sizes in compliance with IEE Wiring Regulations (AM8, AM9). Summary of the task Electrical house wiring regulations are necessary to decide the conductor size of cable for 220-240 V electrical supply under different weather conditions. First, it is necessary to understand the significance of power-flow study to fix the voltage-limits from the source to the load point. Then based on 17th wiring regulations/16th IEE wiring regulations/ National wiring regulations, design the ampere carrying capacity of wires used in a house. Further, recommend the safe and cost-effective earthing technique to avoid from electric shock. You are instructed to read, understand the following points to complete the given Electrical Wiring- Design task for the house: 1. Conduct a power-flow study distribution radial network having 04/05 nodes to understand voltage variation from source to load by assuming load data and line data. 2. Collect the electrical load capacity for all appliances of a sample residential house. 3. Calculate the conductor design current (Ib), nominal current (In), perspective current (Iz), short circuit current (Isc) and % voltage drop for 1-phase, AC supply voltage with following parameters: – Standard insulated conductors for group of 2/3/4/5/6 and clip to a surface. – Cable operating under 03 different ambient temperature conditions. – Refer the Appendix (Page-2) to tabulate the results obtained. 4. Sketch and compare the different type of earthing systems used in Oman/Any other opted country for studies and recommend cost effective suitable earthing system. 5. Calculate the earth fault loop impedance for home selected and justify its need. Scheme: – Abstract & Introduction with citation – Data Selection, Design (Sample Hand Calculations) and implementation steps. – Result Analysis, Conclusion and Recommendations – Report structure in terms of logic and coherence with proper referencing *** Word count: 1650 words *** In-Text Citation and References using Harvard style *** An attachment “Indicative References” has been uploaded for your information
indicative_references.docx

Unformatted Attachment Preview

Indicative References:
Hadi Saadat, 2009. Power System Analysis, McGraw-Hill, ISBN 16th 0-07-012235-0.
International Wire Sales, 2017. https://www.mdm.com/articles/38448-international-wiresales. [Assessed: 27th Jan 2019].
Teng, J.H., 2000. A Network-Topology-based Three-Phase Load Flow for Distribution
Systems. Proc. Natl. Sci. Counc. ROC (A), Vol. 24, No. 4, pp. 259-264. [Online], Available
from: https://ejournal.stpi.narl.org.tw/index/items/download?viId=40AE3F87-1F8E-499B91C5- 4D87B06844F2 [Accessed: 27th Jan 2019].
Pabla A. S, 2004. Electrical Power Distribution, Mc-Graw-Hill, ISBN 10:
0071447830. IET Wiring Regulations 17th Edition, 2008. BS7671 [Online].
Available from: http://electrical.theiet.org/ https://www.landlordcertificates.co.uk/wpcontent/uploads/2016/06/guide-to-the-wiring-regulations.pdf.compressed.pdf [Accessed:
27th Jan 2019].
Pugha, Archie D, 2012. Electrical Transmission & Substation Structures: Solutions to
Building the Grid of Tomorrow. Available from:
http://site.ebrary.com/lib/caledonian/detail.action?adv.x=1&docID=10960910&f00=all&f01=s
ubje
ct&p00=electrical+distribution&p01=%22Electric+Power+Distribution%22+OR+%22Electric+
Utili ties%22+OR+%22Electric+Lines%22. [Accessed: 27th Jan 2019].
Appendix Standards
IEE /IET Wiring
Regulations/
Parameters
Ca
Table 4C1
Cg
Table 4B1
Iz in amps
Iz 
In
Ci Cr Ca Cg
Size in mm2
Table 6A1 and 6A2
Voltage Drop mV/m/A
Table 4D2B
Variation of Ambient Temperature
(www.met.gov.om/opencms/export/sites/default/dgman)
Temperature in…
Temperature
oC
Temperature in…..
in …. oC